BEGIN:VCALENDAR
VERSION:2.0
METHOD:PUBLISH
CALSCALE:GREGORIAN
PRODID:-//WordPress - MECv7.34.2//EN
X-ORIGINAL-URL:https://sebersmedical.com/
X-WR-CALNAME:SEBERS Medical
X-WR-CALDESC:
X-WR-TIMEZONE:Europe/Berlin
BEGIN:VTIMEZONE
TZID:Europe/Berlin
X-LIC-LOCATION:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T030000
RRULE:FREQ=YEARLY;BYMONTH=03;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T020000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=4SU
END:STANDARD
END:VTIMEZONE
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-PUBLISHED-TTL:PT1H
X-MS-OLK-FORCEINSPECTOROPEN:TRUE
BEGIN:VEVENT
CLASS:PUBLIC
UID:MEC-c4015b7f368e6b4871809f49debe0579@sebersmedical.com
DTSTART;TZID=Europe/Berlin:20260731T000000
DTEND;TZID=Europe/Berlin:20260803T000000
DTSTAMP:20260718T155018Z
CREATED:20260718
LAST-MODIFIED:20260718
PRIORITY:5
SEQUENCE:1
TRANSP:OPAQUE
SUMMARY:2026 NYC Neuromodulation Conference
DESCRIPTION:Meet SEBERS Medical at the NYC Neuromodulation Conference\nJoin SEBERS Medical at the NYC Neuromodulation Conference, one of the world’s leading conferences dedicated to neuromodulation, brain stimulation, and neurotechnology. Bringing together neuroscientists, clinicians, engineers, and innovators from around the globe, the conference focuses on the latest advances in Transcranial Magnetic Stimulation (TMS), brain-computer interfaces, EEG-guided neuromodulation, computational modeling, and next-generation brain stimulation technologies.\nAt this year’s conference, SEBERS Medical is proud to present Blossom²—our next-generation research TMS platform developed to enable groundbreaking investigations into neuroplasticity, adaptive neuromodulation, and personalized brain stimulation.\nBlossom² – Designed for the Future of Neuroscience\nBlossom² combines exceptional hardware performance with a fully programmable software architecture, giving researchers the flexibility to develop, reproduce, and optimize advanced stimulation paradigms within a single platform.\nKey features include:\n\nFingerprint TMS™ for individualized stimulation based on each subject’s neurophysiological characteristics\nSingle-pulse, paired-pulse, rTMS, Theta Burst Stimulation (TBS), Quadri-Pulse Stimulation (QPS), individualized iQPS, and freely programmable stimulation protocols\nUltra-fine 100 µs timing resolution for highly precise pulse timing\nProgrammable burst architectures with individually adjustable pulse intervals\nStimulation frequencies up to 1,000 Hz within burst sequences\nAI-ready architecture designed for future intelligent protocol optimization\nOpen interfaces for EEG, EMG, neuronavigation systems, and external research hardware\nAdvanced trigger input and output capabilities for synchronized multimodal experiments\nFlexible software environment supporting custom protocol development and future research applications\n\nThese capabilities make Blossom² an ideal platform for investigating:\n\nNeuroplasticity and cortical physiology\nI-wave-dependent stimulation\nAdaptive neuromodulation\nBrain-state dependent stimulation\nClosed-loop neuromodulation\nBiomarker-guided stimulation\nBrain connectivity and network dynamics\nPersonalized stimulation paradigms\nTranslational neuroscience\n\nPrepared for the Next Generation of Closed-Loop TMS\nAs neuroscience continues to move toward intelligent and adaptive brain stimulation, Blossom² has been designed to provide the technological foundation for future closed-loop TMS research.\nIts open architecture enables seamless integration with external physiological signals, including EEG and EMG, allowing researchers to synchronize stimulation with brain activity and investigate future applications such as AI-assisted protocol optimization, biomarker-driven stimulation, and adaptive neuromodulation strategies.\nTMS Pilot™ – Precision Where It Matters\nVisitors will also experience the TMS Pilot™, our innovative coil-mounted positioning system designed to improve both clinical and research workflows.\nUnlike conventional positioning methods, the TMS Pilot allows users to visualize the stimulation target directly beneath the coil. Real-time visual guidance enables fast, intuitive, and highly reproducible coil placement while simplifying repositioning during longitudinal studies and repeated treatment sessions. The result is improved targeting consistency, greater workflow efficiency, and increased confidence for both researchers and clinicians.\nVisit SEBERS Medical\nWhether you are developing the next generation of brain stimulation technologies, investigating neuroplasticity, advancing EEG-guided neuromodulation, or exploring future closed-loop TMS applications, we invite you to visit SEBERS Medical at the NYC Neuromodulation Conference.\nDiscover how Blossom² and the TMS Pilot™ are enabling researchers to move beyond conventional stimulation protocols toward a new era of programmable, adaptive, and personalized neuromodulation.\nSEBERS Medical – From Clinical Excellence to the Future of Neuroplasticity.\n
URL:https://sebersmedical.com/event/2026-nyc-neuromodulation-conference/
CATEGORIES:Conferences
LOCATION:New York City, NY
ATTACH;FMTTYPE=image/png:https://sebersmedical.com/wp-content/uploads/2026/07/NYC.png
END:VEVENT
END:VCALENDAR
